S K ENGINEERING TENSILE WORK
GST : 27EBFPP3128A1ZY

call images

Call us

07971189683

Auditorium Tensile Structure

Auditorium Tensile Structure
Auditorium Tensile Structure

Auditorium Tensile Structure Specification

  • Dimension (L*W*H)
  • Customizable; Typical 20m x 30m x 12m
  • Insulation
  • Thermal & Acoustic Underlayer
  • Life Span
  • 25-30 years
  • Door Material
  • Powder Coated Metal Doors
  • Open Style
  • Full Span Open; Central High Entrance
  • Window Material
  • Aluminum Frames with Polycarbonate Panels
  • Connection
  • Bolted & Welded Steel Joints
  • Wall Materials
  • Steel Frame with Tensile Fabric Cladding
  • Material
  • High-strength Steel and PVC Composite
  • Roof Material
  • PVC
  • Door
  • Double-leaf, Emergency Exit Doors
  • Thickness Of Wall Panel
  • 60-80 mm
  • Window
  • Natural Light Windows, Skylight included
  • Window Style
  • Fixed & Sliding Available
  • Floor Material
  • Concrete
  • Floor Load
  • Uniformly distributed, 500-1000 kg/m
  • Roof Dead Load
  • 15-30 kg/m
  • Roof Live Load
  • Snow/Wind 40-80 kg/m
  • Earthquake Intensity
  • Designed up to Zone IV
  • Color
  • White
  • Use
  • Auditorium, Event Space
 

Auditorium Tensile Structure Trade Information

  • Minimum Order Quantity
  • 1000 Square Foots
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 100000 Square Foots Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Auditorium Tensile Structure

 Auditorium Tensile Structure is great to be used in auditoriums, stadiums and other large public spaces. It create a dramatic, open-air feel in auditoriums, while still providing the necessary support for the structure. This type of structure is manufactured under the supervision our skilled professionals using excellent quality raw materials with the help of state-of-the-art machinery. It is lightweight, yet strong enough to support large loads. It can also be designed to be fire-resistant and weather-resistant, making it ideal for outdoor use. Offered Auditorium Tensile Structure is available in various specifications as per the precise needs of our clients at nominal rates.

Other Details:

Built Type Modular
Is It Waterproof Waterproof
Height 12 Feet
Cover Material PVC
Tensile Strength 350 Mpa
Pole Material Mild Steel
Color White

 



Superior Safety and Durability

Our auditorium tensile structures are designed to comply with stringent safety standards, including fire resistance certified by ASTM E84 and reinforcement for earthquake intensity up to Zone IV. The galvanized and powder-coated steel frame enhances structural durability, while waterproof PVC roofing and tensile fabric cladding protect against harsh weather and corrosion.


Comfort, Versatility, and Expansion Options

With integrated natural ventilation, acoustic insulation up to 45 dB, and modular adaptability, the structure provides a comfortable environment for events and performances. Customizable dimensions and rapid installation (23 weeks) enable easy scalability and minimal disruption for clients seeking flexible space solutions in various locations.

FAQs of Auditorium Tensile Structure:


Q: How does the auditorium tensile structure ensure fire safety during events?

A: The structures fabric and wall materials are certified to comply with ASTM E84 fire resistance standards, significantly reducing the risk of fire spread and enhancing occupant safety during any event.

Q: What is the process for installing this tensile structure, and how long does it take?

A: Installation typically takes 23 weeks for standard sizes. The process involves assembling the galvanized steel frame with bolted and welded joints, securing the tensile fabric cladding, integrating ventilation louvers and passageways, and performing quality checks to ensure compliance with safety standards.

Q: Where can this auditorium tensile structure be utilized effectively in India?

A: It is ideal for use in auditoriums, event spaces, community centers, and temporary venues, especially in locations requiring robust weather resistance, rapid deployment, and customizable layout. Its modular design enables expansion to suit diverse requirements.

Q: What benefits does integrated lighting and ventilation provide for users?

A: Integrated provision for LED and spotlights ensures optimal illumination for performances and gatherings, while natural ventilation louvers support fresh airflow, reducing the need for mechanical cooling and maintaining comfort inside the venue.

Q: How does the structure handle extreme weather and environmental conditions?

A: The reinforced arch-type framework, combined with waterproof roof and walls, wind resistance up to 150 km/h, and earthquake design up to Zone IV, guarantees stability and protection against heavy rain, strong winds, and seismic activity. UV-resistant materials block over 95% UV rays, preventing fabric degradation.

Q: What maintenance is required and what makes upkeep minimal?

A: Low maintenance is achieved through the use of UV-resistant, anti-mildew, and anti-fungal coatings on all exterior surfaces, reducing the frequency of cleaning and repairs. Occasional inspections and basic upkeep suffice to retain structural integrity and appearance over the 2530 year lifespan.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Tensile Structure Category

Swimming Pool Tensile Cover Structure

Swimming Pool Tensile Cover Structure

Price 350 INR / Square Foot

Minimum Order Quantity : 100 Square Foots

Open Style : Other, Cantilever/Tensile structure

Wall Materials : Other, PVC panels

Earthquake Intensity : Resistant up to 8 grade

Connection : Bolted steel framework

Terres Covar Tensile Structure

Terres Covar Tensile Structure

Price 280 INR / Square Foot

Minimum Order Quantity : 1000 Square Foots

Open Style : Other, Customizable Sliding/Openable

Wall Materials : Other, Glass/Aluminum Composite Panel/Optional

Earthquake Intensity : Designed for Seismic Zones IIIV

Connection : Bolted/Bracketed/Steel Connectors

Modular Tensile Structure

Modular Tensile Structure

Price 350 INR / Square Foot

Minimum Order Quantity : 100 Square Foots

Open Style : Other, Sliding, detachable panels

Wall Materials : Other, Hightensile fabric membrane

Earthquake Intensity : Up to 7.5 Richter

Connection : Galvanised steel connectors, modular fastener system

Waterproof Car Parking Tensile Structure

Waterproof Car Parking Tensile Structure

Price 315 INR / Square Foot

Minimum Order Quantity : 1000 Square Foots

Open Style : Other, Open Sides

Wall Materials : Other, Not Applicable / Open Structure

Earthquake Intensity : Designed According to IS Codes (as per local requirements)

Connection : HighStrength Bolted Connections with Steel Frame